<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Electrodes for Outdoor Field Applications | Sentek</title>
	<atom:link href="https://www.sentek.co.uk/applications/field/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.sentek.co.uk/applications/field/</link>
	<description>The UK's largest independent manufacturer of electrochemical sensors.</description>
	<lastBuildDate>Fri, 17 Apr 2026 12:27:31 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.sentek.co.uk/wp-content/uploads/2021/12/Logo_Mark_Circle-100x100.png</url>
	<title>Electrodes for Outdoor Field Applications | Sentek</title>
	<link>https://www.sentek.co.uk/applications/field/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>OI10/SG/S8 Combination ORP Industrial Electrode</title>
		<link>https://www.sentek.co.uk/product/oi10-sg-s8-combination-orp-industrial-electrode/</link>
		
		<dc:creator><![CDATA[Anna Brown]]></dc:creator>
		<pubDate>Tue, 13 Dec 2022 12:09:02 +0000</pubDate>
				<guid isPermaLink="false">https://sentek.co.uk/?post_type=product&#038;p=2729</guid>

					<description><![CDATA[<p>Industrial glass bodied combination electrode, featuring Ag/AgCl, Gel filled, Double Junction reference with Additional Salt Rings for a long-life sensor. Temperature range of 0 &#8211; 100°C and a measuring range of ± 2000mV. Solid gel probe to minimise poisoning of internal electrode. Sensor is supplied</p>
<p>The post <a href="https://www.sentek.co.uk/product/oi10-sg-s8-combination-orp-industrial-electrode/">OI10/SG/S8 Combination ORP Industrial Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="short_description show"><ul>
<li>Industrial glass bodied combination electrode, featuring Ag/AgCl, Gel filled, Double Junction reference with Additional Salt Rings for a long-life sensor.</li>
<li>Temperature range of 0 &#8211; 100°C and a measuring range of ± 2000mV.</li>
<li>Solid gel probe to minimise poisoning of internal electrode.</li>
<li>Sensor is supplied with an S8 PG13.5 thread connector for convenience, versatility and durability.</li>
</ul>
</div><p>The post <a href="https://www.sentek.co.uk/product/oi10-sg-s8-combination-orp-industrial-electrode/">OI10/SG/S8 Combination ORP Industrial Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>O14/DJ/TEF/S8 Industrial Electrode</title>
		<link>https://www.sentek.co.uk/product/o14-dj-tef-s8-industrial-electrode/</link>
		
		<dc:creator><![CDATA[Anna Brown]]></dc:creator>
		<pubDate>Tue, 13 Dec 2022 11:31:11 +0000</pubDate>
				<guid isPermaLink="false">https://sentek.co.uk/?post_type=product&#038;p=2726</guid>

					<description><![CDATA[<p>Epoxy bodied electrode, featuring Ag/AgCl, Gel filled, Double Junction reference with Additional Salt Rings for a longer life electrode. Designed with a Porous Teflon double junction which provides a longer electrode life in difficult samples where probe blockages have been a problem. Sensor is supplied</p>
<p>The post <a href="https://www.sentek.co.uk/product/o14-dj-tef-s8-industrial-electrode/">O14/DJ/TEF/S8 Industrial Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="short_description show"><ul>
<li>Epoxy bodied electrode, featuring Ag/AgCl, Gel filled, Double Junction reference with Additional Salt Rings for a longer life electrode.</li>
<li>Designed with a Porous Teflon double junction which provides a longer electrode life in difficult samples where probe blockages have been a problem.</li>
<li>Sensor is supplied with an S8 PG13.5 thread connector for convenience and versatility.</li>
</ul>
</div><p>The post <a href="https://www.sentek.co.uk/product/o14-dj-tef-s8-industrial-electrode/">O14/DJ/TEF/S8 Industrial Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>O14/DJ/TEF/1M/BNC Epoxy Combination ORP Electrode</title>
		<link>https://www.sentek.co.uk/product/o14-dj-tef-1m-bnc-epoxy-combination-orp-electrode/</link>
		
		<dc:creator><![CDATA[Anna Brown]]></dc:creator>
		<pubDate>Tue, 13 Dec 2022 10:47:08 +0000</pubDate>
				<guid isPermaLink="false">https://sentek.co.uk/?post_type=product&#038;p=2725</guid>

					<description><![CDATA[<p>Epoxy bodied electrode, featuring Ag/AgCl, Gel filled, Double Junction reference with Additional Salt Rings for a longer life electrode. Designed with a Porous Teflon double junction which allows for use in difficult sticky samples where blockage of a liquid junction is common. Sensor is supplied</p>
<p>The post <a href="https://www.sentek.co.uk/product/o14-dj-tef-1m-bnc-epoxy-combination-orp-electrode/">O14/DJ/TEF/1M/BNC Epoxy Combination ORP Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="short_description show"><ul>
<li>Epoxy bodied electrode, featuring Ag/AgCl, Gel filled, Double Junction reference with Additional Salt Rings for a longer life electrode.</li>
<li>Designed with a Porous Teflon double junction which allows for use in difficult sticky samples where blockage of a liquid junction is common.</li>
<li>Sensor is supplied with 1 metre cable and BNC connector.</li>
</ul>
</div><p>The post <a href="https://www.sentek.co.uk/product/o14-dj-tef-1m-bnc-epoxy-combination-orp-electrode/">O14/DJ/TEF/1M/BNC Epoxy Combination ORP Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>K25/G Glass Bodied K=0.8 Laboratory Conductivity Electrode</title>
		<link>https://www.sentek.co.uk/product/k25-g-glass-bodied-k0-8-laboratory-conductivity-electrode/</link>
					<comments>https://www.sentek.co.uk/product/k25-g-glass-bodied-k0-8-laboratory-conductivity-electrode/#respond</comments>
		
		<dc:creator><![CDATA[Anna Brown]]></dc:creator>
		<pubDate>Mon, 28 Mar 2022 10:57:17 +0000</pubDate>
				<guid isPermaLink="false">https://sentek.co.uk/?post_type=product&#038;p=2509</guid>

					<description><![CDATA[<p>Designed for general purpose water-based conductivity measurements. Particularly good in dirty high conductivity samples and is easily cleaned. Compatible with Thermo Orion, Mettler Toledo, Eutech and WTW instruments. Please specify make and model when enquiring. Perfect for instrument manufacturers to offer as accessories for meters.</p>
<p>The post <a href="https://www.sentek.co.uk/product/k25-g-glass-bodied-k0-8-laboratory-conductivity-electrode/">K25/G Glass Bodied K=0.8 Laboratory Conductivity Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="short_description show"><ul>
<li>Designed for general purpose water-based conductivity measurements.</li>
<li>Particularly good in dirty high conductivity samples and is easily cleaned.</li>
<li>Compatible with Thermo Orion, Mettler Toledo, Eutech and WTW instruments. Please specify make and model when enquiring.</li>
<li>Perfect for instrument manufacturers to offer as accessories for meters.</li>
</ul>
</div><p>The post <a href="https://www.sentek.co.uk/product/k25-g-glass-bodied-k0-8-laboratory-conductivity-electrode/">K25/G Glass Bodied K=0.8 Laboratory Conductivity Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.sentek.co.uk/product/k25-g-glass-bodied-k0-8-laboratory-conductivity-electrode/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>P11 Rod Glass Combination pH Electrode</title>
		<link>https://www.sentek.co.uk/product/p11-rod-glass-combination/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 28 Sep 2021 08:11:25 +0000</pubDate>
				<guid isPermaLink="false">https://sentek.dev-unity.co.uk/?post_type=product&#038;p=760</guid>

					<description><![CDATA[<p>pH electrode with rod shaped membrane for extra strength and durability. Versatile refillable pH probe, featuring an Annular Ceramic junction. Supplied with 1 meter cable and BNC connector.</p>
<p>The post <a href="https://www.sentek.co.uk/product/p11-rod-glass-combination/">P11 Rod Glass Combination pH Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="short_description show"><ul>
<li>pH electrode with rod shaped membrane for extra strength and durability.</li>
<li>Versatile refillable pH probe, featuring an Annular Ceramic junction.</li>
<li>Supplied with 1 meter cable and BNC connector.</li>
</ul>
</div><p>The post <a href="https://www.sentek.co.uk/product/p11-rod-glass-combination/">P11 Rod Glass Combination pH Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fluoride 3221 Combination Ion Selective Electrode</title>
		<link>https://www.sentek.co.uk/product/fluoride-3221-combination-ion-selective-electrode/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 28 Sep 2021 08:11:17 +0000</pubDate>
				<guid isPermaLink="false">https://sentek.dev-unity.co.uk/?post_type=product&#038;p=755</guid>

					<description><![CDATA[<p>Rugged solid-state Fluoride sensor suitable for laboratory and field work. Low maintenance probe that does not require refilling. No need for storage solutions and stored dry for easy and convenient use.</p>
<p>The post <a href="https://www.sentek.co.uk/product/fluoride-3221-combination-ion-selective-electrode/">Fluoride 3221 Combination Ion Selective Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="short_description show"><ul>
<li>Rugged solid-state Fluoride sensor suitable for laboratory and field work.</li>
<li>Low maintenance probe that does not require refilling.</li>
<li>No need for storage solutions. This electrode is stored dry for easy and convenient use.</li>
<li>Easy-to-use electrode with long lifetime.</li>
<li>Can be used with any conventional laboratory or hand held pH meter with a millivolt mode.</li>
<li>Cable length to be specified before ordering. Maximum length is 10 metres. Standard products are fitted with 1 metre of cable terminated with a BNC connector.</li>
</ul>
</div><p>The post <a href="https://www.sentek.co.uk/product/fluoride-3221-combination-ion-selective-electrode/">Fluoride 3221 Combination Ion Selective Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>OI11 Combination PPS ORP Industrial Electrode</title>
		<link>https://www.sentek.co.uk/product/oi11-industrial-electrode/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 28 Sep 2021 08:10:04 +0000</pubDate>
				<guid isPermaLink="false">https://sentek.dev-unity.co.uk/?post_type=product&#038;p=641</guid>

					<description><![CDATA[<p>Glass filled PPS combination electrode for super rugged dip type ORP measurements. This probe features 3/4&#8243; NPT thread size at both ends to enable thread mounting in a pipe for dip measurements, or to screw into a ‘T’ for flow line measurements. Porous Teflon junction</p>
<p>The post <a href="https://www.sentek.co.uk/product/oi11-industrial-electrode/">OI11 Combination PPS ORP Industrial Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="short_description show"><ul>
<li>Glass filled PPS combination electrode for super rugged dip type ORP measurements.</li>
<li>This probe features 3/4&#8243; NPT thread size at both ends to enable thread mounting in a pipe for dip measurements, or to screw into a ‘T’ for flow line measurements.</li>
<li>Porous Teflon junction sensor, with Platinum Band sensing element.</li>
<li>Temperature range of 0 &#8211; 100°C and a measuring range of ± 2000mV.</li>
<li>Sensor is supplied with a 5 metre fixed cable and BNC connector.</li>
</ul>
</div><p>The post <a href="https://www.sentek.co.uk/product/oi11-industrial-electrode/">OI11 Combination PPS ORP Industrial Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>K25 General Purpose K=0.55 Laboratory Conductivity Electrode</title>
		<link>https://www.sentek.co.uk/product/k25-general-purpose-laboratory-conductivity-electrode/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 28 Sep 2021 08:09:42 +0000</pubDate>
				<guid isPermaLink="false">https://sentek.dev-unity.co.uk/?post_type=product&#038;p=615</guid>

					<description><![CDATA[<p>Epoxy bodied, 4-pole conductivity electrode with carbon plates, K=0.55 cell constant and optional ATC. When ordering conductivity cells please specify make and model of conductivity meter.</p>
<p>The post <a href="https://www.sentek.co.uk/product/k25-general-purpose-laboratory-conductivity-electrode/">K25 General Purpose K=0.55 Laboratory Conductivity Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="short_description show"><p>Epoxy bodied, 4-pole conductivity electrode with carbon plates, K=0.55 cell constant and optional ATC.</p>
<p>When ordering conductivity cells please specify make and model of conductivity meter.</p>
</div><p>The post <a href="https://www.sentek.co.uk/product/k25-general-purpose-laboratory-conductivity-electrode/">K25 General Purpose K=0.55 Laboratory Conductivity Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>R1 AgCl Glass Reference Electrode</title>
		<link>https://www.sentek.co.uk/product/r1-ag-reference-electrode/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 28 Sep 2021 08:09:41 +0000</pubDate>
				<guid isPermaLink="false">https://sentek.dev-unity.co.uk/?post_type=product&#038;p=606</guid>

					<description><![CDATA[<p>AgCl Glass reference electrode for use with pH, ORP (Redox) and Ion Selective Electrodes. Built within a 12mm diameter glass body and with a cermaic frit junction. Refillable electrode with Ag/AgCl system. Supplied with a 1 meter cable and 2mm pin plug.</p>
<p>The post <a href="https://www.sentek.co.uk/product/r1-ag-reference-electrode/">R1 AgCl Glass Reference Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="short_description show"><ul>
<li>AgCl Glass reference electrode for use with pH, ORP (Redox) and Ion Selective Electrodes.</li>
<li>Built within a 12mm diameter glass body and with a cermaic frit junction.</li>
<li>Refillable electrode with Ag/AgCl system.</li>
<li>Supplied with a 1 meter cable and 2mm pin plug.</li>
</ul>
</div><p>The post <a href="https://www.sentek.co.uk/product/r1-ag-reference-electrode/">R1 AgCl Glass Reference Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>R2 AgCl Glass Double Junction Reference Electrode</title>
		<link>https://www.sentek.co.uk/product/r2-agcl-double-junction-reference-electrode/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 28 Sep 2021 08:09:41 +0000</pubDate>
				<guid isPermaLink="false">https://sentek.dev-unity.co.uk/?post_type=product&#038;p=607</guid>

					<description><![CDATA[<p>The post <a href="https://www.sentek.co.uk/product/r2-agcl-double-junction-reference-electrode/">R2 AgCl Glass Double Junction Reference Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="short_description show"></div><p>The post <a href="https://www.sentek.co.uk/product/r2-agcl-double-junction-reference-electrode/">R2 AgCl Glass Double Junction Reference Electrode</a> appeared first on <a href="https://www.sentek.co.uk">Sentek Limited</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
